Tripp Lite SV40KM2P4B uninterruptible power supply (UPS) Double-conversion (Online) 40 kVA 36000 W

Tripp Lite SV40KM2P4B. UPS topology: Double-conversion (Online), Output power capacity: 40 kVA, Output power: 36000 W. AC outlet types: Terminal, Power plug: Terminal, Serial interface type: RS-232. Typical backup time at full load: 10 min, Typical backup time at half load: 22 min. Form factor: Tower, Product color: Black, Housing material: Steel. Width: 4.21" (106.9 mm), Depth: 30.2" (766.8 mm), Height: 79.1" (2009.9 mm)
Manufacturer: Tripp Lite
SKU: 5053232
Manufacturer part number: SV40KM2P4B
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
The SV40KM2P4B SmartOnline® SV Series 40kVA 3-Phase On-Line Double-Conversion UPS System delivers true scalability and offers the highest level of secure, uninterrupted power protection. Featuring a modular, scalable design with high-efficiency voltage and frequency independent (VFI) operation, this on-line UPS system is ideal for protecting a variety of critical IT systems. The SV40KM2P4B includes pre-installed input, bypass and output breakers, as well as a static transfer switch (STS), two 20kVA SV20PM power modules and four SVBM battery modules. Space is included for up to two additional user-installable SV20PM power modules. External ±120VDC battery options, such as BP240V370, are also available from Tripp Lite for even more extended runtime. The Java-free HTML5-based WEBCARDLX interface enables full remote access for site power and UPS status monitoring, configuration, control and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. With up to 92% efficiency in standard mode and up to 99% efficiency in optional economy mode, this 40kVA UPS system helps you reduce operating and cooling costs. Automatic and manual bypass options keep connected equipment operational during routine maintenance or critical power module failure. Front-panel display offers full UPS condition and status reporting.
40kVA 36kW 3-Phase Medium-Chassis UPS System - Supports 208/120V or 220/127V AC 50/60Hz Wye 4-wire plus Earth hardwire input and output wiring - Dual hardwire input design enables operation from up to 2 power sources - Network-grade sine-wave AC output with 1% output voltage regulation and less than 1% output total harmonic distortion - Tested to UL 1778 (U.S.), CSA (Canada) and NOM (Mexico) standards - High 0.9 power factor for maximum power to the connected load Pre-Installed WEBCARDLX Network Interface - Allows full remote access for power monitoring, configuration, control and email notifications via secure web browser, SNMP, telnet or SSH - Supports 10/100 Mbps auto-sensing for communication with an Ethernet network - Optional EnviroSense2 sensors (sold separately) enable site monitoring of temperature, humidity and contact-closure status - No Java required Modular, Scalable Design for Maximum Flexibility - Modular configuration with hot-swappable power modules and batteries enables easy, fast maintenance with zero downtime - Open slots for up to 2 additional 20kVA SV20PM power modules accommodate increased capacity up to 80kVA (or 60kVA with N+1 fault tolerance) - Supports external ±120VDC battery options for even more extended runtime Optional Economy Mode - Up to 99% efficient in optional economy mode to lower operating and cooling costs Wide Input/Narrow Output Voltage Operating Range - Enables full continuous online operation during brownouts as low as 121V and overvoltages up to 253V - Regulates output voltage within 1% of the selected nominal output voltage in on-line double-conversion mode Advanced IGBT Inverter with Digital Signal Processor (DSP) Technology - Provides for less than 2% input total harmonic distortion (THDi) to support 1:1 generator sizing and prevent the need to oversize generator systems relative to UPS capacity Automatic and Manual Bypass Options - Keep connected equipment operational during routine maintenance or critical power module failure
The SV40KM2P4B SmartOnline® SV Series 40kVA 3-Phase On-Line Double-Conversion UPS System delivers true scalability and offers the highest level of secure, uninterrupted power protection. Featuring a modular, scalable design with high-efficiency voltage and frequency independent (VFI) operation, this on-line UPS system is ideal for protecting a variety of critical IT systems. The SV40KM2P4B includes pre-installed input, bypass and output breakers, as well as a static transfer switch (STS), two 20kVA SV20PM power modules and four SVBM battery modules. Space is included for up to two additional user-installable SV20PM power modules. External ±120VDC battery options, such as BP240V370, are also available from Tripp Lite for even more extended runtime. The Java-free HTML5-based WEBCARDLX interface enables full remote access for site power and UPS status monitoring, configuration, control and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. With up to 92% efficiency in standard mode and up to 99% efficiency in optional economy mode, this 40kVA UPS system helps you reduce operating and cooling costs. Automatic and manual bypass options keep connected equipment operational during routine maintenance or critical power module failure. Front-panel display offers full UPS condition and status reporting.
40kVA 36kW 3-Phase Medium-Chassis UPS System - Supports 208/120V or 220/127V AC 50/60Hz Wye 4-wire plus Earth hardwire input and output wiring - Dual hardwire input design enables operation from up to 2 power sources - Network-grade sine-wave AC output with 1% output voltage regulation and less than 1% output total harmonic distortion - Tested to UL 1778 (U.S.), CSA (Canada) and NOM (Mexico) standards - High 0.9 power factor for maximum power to the connected load Pre-Installed WEBCARDLX Network Interface - Allows full remote access for power monitoring, configuration, control and email notifications via secure web browser, SNMP, telnet or SSH - Supports 10/100 Mbps auto-sensing for communication with an Ethernet network - Optional EnviroSense2 sensors (sold separately) enable site monitoring of temperature, humidity and contact-closure status - No Java required Modular, Scalable Design for Maximum Flexibility - Modular configuration with hot-swappable power modules and batteries enables easy, fast maintenance with zero downtime - Open slots for up to 2 additional 20kVA SV20PM power modules accommodate increased capacity up to 80kVA (or 60kVA with N+1 fault tolerance) - Supports external ±120VDC battery options for even more extended runtime Optional Economy Mode - Up to 99% efficient in optional economy mode to lower operating and cooling costs Wide Input/Narrow Output Voltage Operating Range - Enables full continuous online operation during brownouts as low as 121V and overvoltages up to 253V - Regulates output voltage within 1% of the selected nominal output voltage in on-line double-conversion mode Advanced IGBT Inverter with Digital Signal Processor (DSP) Technology - Provides for less than 2% input total harmonic distortion (THDi) to support 1:1 generator sizing and prevent the need to oversize generator systems relative to UPS capacity Automatic and Manual Bypass Options - Keep connected equipment operational during routine maintenance or critical power module failure
Products specifications
Attribute nameAttribute value
Package volume883000 cm³
Country of OriginChina
Width4.21"
Depth30.2"
Height79.1"
Weight604.7 lbs
Housing MaterialSteel
Emergency Power Off (EPO)Y
Input Frequency40 - 70 Hz
Display TypeLCD
Power factor0.9
Input current Total Harmonic Distortion (THD)2 %
Input power factor0.99
UPS topologyDouble-conversion (Online)
Serial interfaceY
Master (outer) case weight76.9 lbs
Master (outer) case length34.3"
Master (outer) case width11.6"
Master (outer) case height9.84"
Output voltage regulation1 %
Number of input phases3
EMI/RFI noise filteringY
Cold startY
Crest factor3:1
Number of output phases3
Emergency Power Off (EPO) connectorY
Features
Cooling typeActive
LED indicatorsY
Output power36000 W
Noise level73 dB
Audible alarm(s)Y
Surge energy rating2496 J
Input operation voltage (min)120 V
Input operation voltage (max)220 V
Output operation voltage (min)120 V
Output operation voltage (max)220 V
Efficiency92 %
Output voltage Total Harmonic Distortion (THD)1.5 %
WaveformSine
Audible alarm modesAlarm when on battery, Fault, Low battery alarm
Surge protectionY
Packaging content
ManualY
Design
Form factorTower
Operational conditions
Operating temperature (T-T)0 - 40 °C
Storage temperature (T-T)-15 - 60 °C
Operating relative humidity (H-H)0 - 95 %
Operating altitude0 - 39370.1"
Ports & interfaces
AC outlet typesTerminal
Power plugTerminal
Management features
Web-based managementY
Technical details
Product colorBlack
Sustainability certificatesRoHS
Serial interface typeRS-232
Power
Maximum current120 A
Output power capacity40 kVA
Packaging data
Package width11.6"
Package depth34.3"
Package height85.6"
Package weight739.7 lbs
Logistics data
Quantity per master (outer) case1 pc(s)
Battery
Typical backup time at full load10 min
Typical backup time at half load22 min
Hot-swap batteryY
*
*
*
Products specifications
Attribute nameAttribute value
Package volume883000 cm³
Country of OriginChina
Width4.21"
Depth30.2"
Height79.1"
Weight604.7 lbs
Housing MaterialSteel
Emergency Power Off (EPO)Y
Input Frequency40 - 70 Hz
Display TypeLCD
Power factor0.9
Input current Total Harmonic Distortion (THD)2 %
Input power factor0.99
UPS topologyDouble-conversion (Online)
Serial interfaceY
Master (outer) case weight76.9 lbs
Master (outer) case length34.3"
Master (outer) case width11.6"
Master (outer) case height9.84"
Output voltage regulation1 %
Number of input phases3
EMI/RFI noise filteringY
Cold startY
Crest factor3:1
Number of output phases3
Emergency Power Off (EPO) connectorY
Features
Cooling typeActive
LED indicatorsY
Output power36000 W
Noise level73 dB
Audible alarm(s)Y
Surge energy rating2496 J
Input operation voltage (min)120 V
Input operation voltage (max)220 V
Output operation voltage (min)120 V
Output operation voltage (max)220 V
Efficiency92 %
Output voltage Total Harmonic Distortion (THD)1.5 %
WaveformSine
Audible alarm modesAlarm when on battery, Fault, Low battery alarm
Surge protectionY
Packaging content
ManualY
Design
Form factorTower
Operational conditions
Operating temperature (T-T)0 - 40 °C
Storage temperature (T-T)-15 - 60 °C
Operating relative humidity (H-H)0 - 95 %
Operating altitude0 - 39370.1"
Ports & interfaces
AC outlet typesTerminal
Power plugTerminal
Management features
Web-based managementY
Technical details
Product colorBlack
Sustainability certificatesRoHS
Serial interface typeRS-232
Power
Maximum current120 A
Output power capacity40 kVA
Packaging data
Package width11.6"
Package depth34.3"
Package height85.6"
Package weight739.7 lbs
Logistics data
Quantity per master (outer) case1 pc(s)
Battery
Typical backup time at full load10 min
Typical backup time at half load22 min
Hot-swap batteryY
Product tags
  • (92706)