Raritan PX3-5085U-N2 power distribution unit (PDU) 48 AC outlet(s) 0U Black

6297913
Raritan PX3-5085U-N2. PDU types: Monitored, Switched, Rack capacity: 0U, Type: Three-phase. AC outlets quantity: 48 AC outlet(s), AC outlet types: C13 coupler, C19 coupler, Power plug: IEC 320. Cable length: 118.1" (3 m). Monitoring: Humidity, Temperature. Nominal input voltage: 400 V, Maximum current: 30 A, AC input frequency: 50 - 60 Hz

Raritan DSX2-8M console server RJ-45

4814581
Raritan DSX2-8M. Management protocols: SNMP. Authentication method: Radius, Security algorithms: 802.1x RADIUS. Console port: RJ-45. Power source type: AC, AC input voltage: 100-240 V, AC input frequency: 50 - 60 Hz. Certification: CE, FCC 15 A, US UL

Raritan PX3-5551V-E2V2 power distribution unit (PDU) 24 AC outlet(s) 0U Black

5551541
Raritan PX3-5551V-E2V2. PDU types: Monitored, Switched, Rack capacity: 0U, Type: Three-phase. AC outlets quantity: 24 AC outlet(s), AC outlet types: C13 coupler, C19 coupler, Power plug: IEC 320. LED indicators: Status, Cable length: 118.1" (3 m). Monitoring: Humidity, Temperature. Nominal input voltage: 208 V, Maximum current: 60 A, AC input frequency: 50 - 60 Hz

Raritan PX3-4905V-V2 power distribution unit (PDU) 36 AC outlet(s) 0U Black

5730273
Raritan PX3-4905V-V2. PDU types: Monitored, Rack capacity: 0U, Type: Three-phase. AC outlets quantity: 36 AC outlet(s), AC outlet types: C13 coupler, C19 coupler, Power plug: IEC 320. LED indicators: Status, Cable length: 118.1" (3 m), Security algorithms: HTTPS, SSH. Monitoring: Current, Power, Voltage. Nominal input voltage: 208 V, Maximum current: 60 A, AC input frequency: 50 - 60 Hz

Raritan PX3-4905U-V2 power distribution unit (PDU) 36 AC outlet(s) 0U Black

5955945
Raritan PX3-4905U-V2. PDU types: Monitored, Rack capacity: 0U, Type: Three-phase. AC outlets quantity: 36 AC outlet(s), AC outlet types: C13 coupler, C19 coupler, Power plug: IEC 320. Cable length: 118.1" (3 m), Security algorithms: HTTPS, SSH. Monitoring: Current, Power, Voltage. Nominal input voltage: 208 V, Maximum current: 60 A, AC input frequency: 50 - 60 Hz

Raritan PX3-5541R-E2 power distribution unit (PDU) 18 AC outlet(s) 2U Black

6474331
Raritan PX3-5541R-E2. PDU types: Monitored, Switched, Rack capacity: 2U, Type: Three-phase. AC outlets quantity: 18 AC outlet(s), AC outlet types: C13 coupler, C19 coupler, Power plug: IEC 60320. LED indicators: Status, Cable length: 118.1" (3 m). Monitoring: Power, Voltage. Nominal input voltage: 208 V, Maximum current: 60 A, AC input frequency: 50 - 60 Hz