Raritan PX3-4782V-V2 power distribution unit (PDU) 48 AC outlet(s) 0U Black

Raritan PX3-4782V-V2. PDU types: Monitored, Rack capacity: 0U, Type: Three-phase. AC outlets quantity: 48 AC outlet(s), AC outlet types: C13 coupler, C19 coupler, Power plug: IEC 320. LED indicators: Status, Cable length: 118.1" (3 m). Monitoring: Humidity, Temperature. Nominal input voltage: 400 V, Maximum current: 63 A, AC input frequency: 50 - 60 Hz
Manufacturer: Raritan
SKU: 6367056
Manufacturer part number: PX3-4782V-V2
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Monitored rack power distribution unit (0U [vertical], 43.6kVA, 48 outlets). INPUT: 400v (3-phase WYE), 63a - IEC 60309 3P+N+E 6h 63A plug (4P5W); OUTPUT: 36@ C13, 12@ C19 outlets; on 12@ 1-pole, 16a Overcurrent Protectors; FEATURES: Billing-Grade (+/- 1%) Energy Metering [kW, kVA, V, A, Power Factor] - per inlet, per breaker/fuse, per outlet; Remote network monitoring via HTML, JSON-RPC, SSH, Telnet, MODBUS/TCP, and SNMPv3. Onboard embedded processor with minimum 536MHz clock speed, 16MB SPI Flash, and 64MB DDR2 RAM. Cascading upto 16 PDU's using single Ethernet or USB connection. Environmental monitoring [temp/humidity] capable – up to 32 sensors. Individual outlet numbers labeled on chassis. Automated deployment via TFTP, DHCP, SSH(CLI), or USB Flash Drives. WiFi Capable. USB Webcam Capable. iPad/iPhone/Android App. Dual 10/100/1000 Ethernet port. Tri-color status LED per receptacle. Breaker metering and alarming (0V detection). Max Dimensions 109mm x 80mm x 1780mm (4.3in x 3.1in x 70.1in). Max Weight TBD. Maximum ambient temperature 60C at full load.

 

  • Securelock
  • Removable Controller
  • Embedded Processor: ARM Cortex A5 500MHZ (Atmel A5D21C), 16MB SPI Flash, 128MB DDR2 RAM
Monitored rack power distribution unit (0U [vertical], 43.6kVA, 48 outlets). INPUT: 400v (3-phase WYE), 63a - IEC 60309 3P+N+E 6h 63A plug (4P5W); OUTPUT: 36@ C13, 12@ C19 outlets; on 12@ 1-pole, 16a Overcurrent Protectors; FEATURES: Billing-Grade (+/- 1%) Energy Metering [kW, kVA, V, A, Power Factor] - per inlet, per breaker/fuse, per outlet; Remote network monitoring via HTML, JSON-RPC, SSH, Telnet, MODBUS/TCP, and SNMPv3. Onboard embedded processor with minimum 536MHz clock speed, 16MB SPI Flash, and 64MB DDR2 RAM. Cascading upto 16 PDU's using single Ethernet or USB connection. Environmental monitoring [temp/humidity] capable – up to 32 sensors. Individual outlet numbers labeled on chassis. Automated deployment via TFTP, DHCP, SSH(CLI), or USB Flash Drives. WiFi Capable. USB Webcam Capable. iPad/iPhone/Android App. Dual 10/100/1000 Ethernet port. Tri-color status LED per receptacle. Breaker metering and alarming (0V detection). Max Dimensions 109mm x 80mm x 1780mm (4.3in x 3.1in x 70.1in). Max Weight TBD. Maximum ambient temperature 60C at full load.

 

  • Securelock
  • Removable Controller
  • Embedded Processor: ARM Cortex A5 500MHZ (Atmel A5D21C), 16MB SPI Flash, 128MB DDR2 RAM
Products specifications
Attribute nameAttribute value
Load Capacity41500 VA
Block 1 output current10 A
Width4.29"
Depth3.15"
Height70.1"
MountingVertical
DisplayLCD
Cable Length118.1"
TypeThree-phase
MonitoringHumidity, Temperature
Block 2 output current16 A
Features
Output voltage220 - 240 V
Rack capacity0U
LED indicatorsStatus
Design
PDU typesMonitored
Operational conditions
Operating temperature (T-T)0 - 60 °C
Storage temperature (T-T)-25 - 65 °C
Operating relative humidity (H-H)0 - 85 %
Storage relative humidity (H-H)0 - 100 %
Operating altitude0 - 72000"
Non-operating altitude0 - 120000"
Ports & interfaces
AC outlets quantity48 AC outlet(s)
AC outlet typesC13 coupler, C19 coupler
Ethernet LAN (RJ-45) ports2
USB ports quantity3
Power plugIEC 320
Technical details
Product colorBlack
Power
Maximum current63 A
Nominal input voltage400 V
AC input frequency50 - 60 Hz
Power protection featuresOverload
Other features
Nominal output voltage230 V
Packaging data
Package height83.1"
Package width14.6"
Package depth6.3"
*
*
*
Products specifications
Attribute nameAttribute value
Load Capacity41500 VA
Block 1 output current10 A
Width4.29"
Depth3.15"
Height70.1"
MountingVertical
DisplayLCD
Cable Length118.1"
TypeThree-phase
MonitoringHumidity, Temperature
Block 2 output current16 A
Features
Output voltage220 - 240 V
Rack capacity0U
LED indicatorsStatus
Design
PDU typesMonitored
Operational conditions
Operating temperature (T-T)0 - 60 °C
Storage temperature (T-T)-25 - 65 °C
Operating relative humidity (H-H)0 - 85 %
Storage relative humidity (H-H)0 - 100 %
Operating altitude0 - 72000"
Non-operating altitude0 - 120000"
Ports & interfaces
AC outlets quantity48 AC outlet(s)
AC outlet typesC13 coupler, C19 coupler
Ethernet LAN (RJ-45) ports2
USB ports quantity3
Power plugIEC 320
Technical details
Product colorBlack
Power
Maximum current63 A
Nominal input voltage400 V
AC input frequency50 - 60 Hz
Power protection featuresOverload
Other features
Nominal output voltage230 V
Packaging data
Package height83.1"
Package width14.6"
Package depth6.3"