Eaton EHBPL3000R-PDU1U. PDU types: Basic, Rack capacity: 1U. AC outlets quantity: 5 AC outlet(s), AC outlet types: NEMA 5–20R, Power plug: NEMA L5-30P. Nominal input voltage: 100-127 V, Maximum current: 24 A, AC input frequency: 50 - 60 Hz. Dimensions (WxDxH): 17.3 x 3.78 x 2.01" (439 x 96 x 51 mm)
Eaton PWATSS520003. PDU types: Switched, Rack capacity: 1U, Mounting: Horizontal. AC outlets quantity: 8 AC outlet(s), AC outlet types: NEMA 5–15R, Power plug: NEMA 5–20P. Cable length: 78.7" (2 m). Nominal input voltage: 120 V, Maximum current: 16 A. Dimensions (WxDxH): 19 x 6.97 x 1.73" (482 x 177 x 44 mm)
Geist I10001. PDU types: Basic, Mounting: Vertical, Housing material: Steel. AC outlets quantity: 24 AC outlet(s), AC outlet types: NEMA 5–20R, Power plug: NEMA 5–20P. Cable length: 118.1" (3 m), Certification: UL & c-UL 60950. Nominal input voltage: 120 V, Maximum current: 20 A, AC input frequency: 50 - 60 Hz. Dimensions (WxDxH): 2 x 2 x 66.2" (50.8 x 50.8 x 1682 mm)
Eaton TPC115-10D-MTR. Rack capacity: 1U, Type: Single-phase, Mounting: Horizontal. AC outlets quantity: 10 AC outlet(s), AC outlet types: NEMA 5-20R, Power plug: NEMA L5-30P. Nominal input voltage: 110 - 125 V, Maximum current: 24 A, AC input frequency: 50/60 Hz
Eaton TPC115-10C-MTR. Rack capacity: 1U, Type: Single-phase, Mounting: Horizontal. AC outlets quantity: 10 AC outlet(s), AC outlet types: NEMA 5–15R, Power plug: NEMA L5-30P. Nominal input voltage: 110 - 125 V, Maximum current: 24 A, AC input frequency: 50/60 Hz
Tripp Lite PDUMH15HVNET. PDU types: Switched, Rack capacity: 1U, Mounting: Horizontal. AC outlets quantity: 8 AC outlet(s), AC outlet types: C13 coupler, Power plug: C14 coupler. Cable length: 78.7" (2 m), Certification: UL 60950-1 (USA, Canada), Class A (Emissions), NOM (Mexico), CE (IEC 60950). Nominal input voltage: 200-240 V, Maximum current: 15 A, AC input frequency: 50 - 60 Hz. Width: 14.8" (375.2 mm), Depth: 17.3" (440.2 mm), Dimensions (WxDxH): 17.3 x 14.8 x 1.13" (439 x 376 x 28.7 mm)
Tripp Lite PDUMH20AT. PDU types: Metered, Rack capacity: 1U, Mounting: Horizontal. AC outlets quantity: 16 AC outlet(s), AC outlet types: NEMA 5–15R, NEMA 5–20R, Input connection type: NEMA 5-20P, NEMA L5-20P. Cable length: 141.7" (3.6 m), Certification: UL 60950-1, CSA, Class A, NOM. Nominal input voltage: 100-127 V, Maximum current: 20 A, AC input frequency: 60 Hz. Width: 17.5" (444.5 mm), Depth: 14.5" (368.3 mm), Dimensions (WxDxH): 17.5 x 14.5 x 1.75" (444 x 368 x 44.4 mm)
HPE P9Q42A. PDU types: Basic, Rack capacity: 0U, Type: Single-phase. AC outlets quantity: 42 AC outlet(s), AC outlet types: C13 coupler, C19 coupler, Power plug: NEMA L6-30P. Nominal input voltage: 208 V, Maximum current: 24 A, AC input frequency: 50 - 60 Hz. Dimensions (WxDxH): 58.7 x 2.09 x 2.05" (1490 x 53 x 52 mm), Weight: 12.6 lbs (5.7 kg)
Tripp Lite PDUMV30HV2. PDU types: Metered, Rack capacity: 0U, Mounting: Vertical. AC outlets quantity: 48 AC outlet(s), AC outlet types: C13 coupler, C19 coupler, Power plug: NEMA L6-30P. Cable length: 118.1" (3 m). Nominal input voltage: 200-240 V, Maximum current: 30 A, AC input frequency: 50 - 60 Hz. Width: 2.17" (55.1 mm), Depth: 2.52" (64 mm), Dimensions (WxDxH): 1.97 x 2.52 x 70" (50 x 64 x 1778 mm)
Eaton TPC115-10F-LTR. Rack capacity: 1U, Type: Single-phase, Mounting: Horizontal. AC outlets quantity: 10 AC outlet(s), AC outlet types: NEMA 6–15, Power plug: NEMA L6-30P. Nominal input voltage: 110 - 125 V, Maximum current: 24 A, AC input frequency: 50/60 Hz