Hewlett Packard Enterprise SN6630C Managed None 2U Gray

Hewlett Packard Enterprise SN6630C. Switch type: Managed. Basic switching RJ-45 Ethernet ports type: None, Installed SFP+ modules quantity: 96. Rack mounting, Form factor: 2U
SKU: 7232240
Manufacturer part number: R4D92A
GTIN: 0190017426839
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Are you looking to modernize your storage network? The all-flash data center and emerging NVMe storage requires a modern storage network that can keep up with pace of innovation seen with compute and storage resources. The HPE C-series SN6630C 96-port 32Gb Fibre Channel (FC) Switch is the next generation 96-port 2-rack unit FC switch that provides high-speed Fibre Channel connectivity in the SAN. This switch offers state-of-art analytics and telemetry capability built into its next-generation Application-Specific Integrated Circuit (ASIC) platform. The Non-Volatile Memory express (NVMe)-ready switch allows a seamless transition to Fibre Channel Non-Volatile Memory Express (FC-NVMe) workloads whenever available without any hardware upgrade in the SAN. This high-density, highly reliable, and scalable, enterprise-class switch is ideal for medium to large departmental SANs. Features High-speed Flash-ready Performance - HPE C-series SN6630C Fibre Channel Switch with centralized non-blocking arbitration, provides consistent 32 Gbps low-latency performance across traffic conditions for every Fibre Channel port on the switch. - Delivers increased performance with an aggregate bandwidth of 3 Tbps for growing and dynamic workloads. - It offers state-of-the-art SAN Insights (analytics) and telemetry capabilities that have been built into this next-generation hardware platform. - FC-NVMe-ready SAN switch with enhanced buffer-to-buffer (B2B) credits connecting both storage and host ports and FC link encryption. More Flexibility - HPE C-series SN6630C Fibre Channel Switch provides an option to deploy as few as 48 32-Gbps FC ports in the entry-level variant, and then grow in increments of 16 ports to up to 96 ports. This allows four possible configurations of 48, 64, 80, and 96 ports. - The 32 Gbps ports allow users to deploy them on existing 16 or 8 Gbps transceivers, reducing initial CapEx and investment protection with an option to upgrade to 32 Gbps transceivers and adapters whenever needed. - Increased fabric scalability provides more flexibility for a variety of SAN architectures. Easy Manageability - HPE C-series SN6630C Fibre Channel Switch supports enhanced diagnostic features such as inter-switch link (ISL) and host-bus-adapter (HBA) diagnostics, read diagnostic parameters, link cable beacon, and advanced reliability features such as forward error correction (FEC) with HBA ports. - Cisco Data Center Network Manager Essentials Edition software, included with the switch, provides a centralized management tool with task-based wizards that simplifies management of switches and fabrics. Additional advanced features are available with the DCNM licensed version, sold separately. - Cisco SAN Insights delivers deep visibility into I/O traffic between the compute and the storage infrastructure. This information is in addition to the already-available visibility obtained from individual ports, switches, servers, virtual machines, and storage arrays. Intelligent Network Services for SAN - HPE C-series SN6630C Fibre Channel Switch supports slow-drain detection and isolation, virtual SAN (vSAN) technology, access control lists for hardware-based intelligent frame processing, smart zoning, and other various services. - Provides visibility into all virtual machines that are accessing the storage LUNs in the fabric and offers an end-to-end view for analytics. - Delivers powerful representational state transfer (REST) and NX-API capabilities to enable flexible and rapid programming of utilities for the SAN.
Are you looking to modernize your storage network? The all-flash data center and emerging NVMe storage requires a modern storage network that can keep up with pace of innovation seen with compute and storage resources. The HPE C-series SN6630C 96-port 32Gb Fibre Channel (FC) Switch is the next generation 96-port 2-rack unit FC switch that provides high-speed Fibre Channel connectivity in the SAN. This switch offers state-of-art analytics and telemetry capability built into its next-generation Application-Specific Integrated Circuit (ASIC) platform. The Non-Volatile Memory express (NVMe)-ready switch allows a seamless transition to Fibre Channel Non-Volatile Memory Express (FC-NVMe) workloads whenever available without any hardware upgrade in the SAN. This high-density, highly reliable, and scalable, enterprise-class switch is ideal for medium to large departmental SANs. Features High-speed Flash-ready Performance - HPE C-series SN6630C Fibre Channel Switch with centralized non-blocking arbitration, provides consistent 32 Gbps low-latency performance across traffic conditions for every Fibre Channel port on the switch. - Delivers increased performance with an aggregate bandwidth of 3 Tbps for growing and dynamic workloads. - It offers state-of-the-art SAN Insights (analytics) and telemetry capabilities that have been built into this next-generation hardware platform. - FC-NVMe-ready SAN switch with enhanced buffer-to-buffer (B2B) credits connecting both storage and host ports and FC link encryption. More Flexibility - HPE C-series SN6630C Fibre Channel Switch provides an option to deploy as few as 48 32-Gbps FC ports in the entry-level variant, and then grow in increments of 16 ports to up to 96 ports. This allows four possible configurations of 48, 64, 80, and 96 ports. - The 32 Gbps ports allow users to deploy them on existing 16 or 8 Gbps transceivers, reducing initial CapEx and investment protection with an option to upgrade to 32 Gbps transceivers and adapters whenever needed. - Increased fabric scalability provides more flexibility for a variety of SAN architectures. Easy Manageability - HPE C-series SN6630C Fibre Channel Switch supports enhanced diagnostic features such as inter-switch link (ISL) and host-bus-adapter (HBA) diagnostics, read diagnostic parameters, link cable beacon, and advanced reliability features such as forward error correction (FEC) with HBA ports. - Cisco Data Center Network Manager Essentials Edition software, included with the switch, provides a centralized management tool with task-based wizards that simplifies management of switches and fabrics. Additional advanced features are available with the DCNM licensed version, sold separately. - Cisco SAN Insights delivers deep visibility into I/O traffic between the compute and the storage infrastructure. This information is in addition to the already-available visibility obtained from individual ports, switches, servers, virtual machines, and storage arrays. Intelligent Network Services for SAN - HPE C-series SN6630C Fibre Channel Switch supports slow-drain detection and isolation, virtual SAN (vSAN) technology, access control lists for hardware-based intelligent frame processing, smart zoning, and other various services. - Provides visibility into all virtual machines that are accessing the storage LUNs in the fabric and offers an end-to-end view for analytics. - Delivers powerful representational state transfer (REST) and NX-API capabilities to enable flexible and rapid programming of utilities for the SAN.
Products specifications
Attribute nameAttribute value
Installed SFP+ modules quantity96
SFP+ module slots quantity96
Width17.4"
Depth22.3"
Height3.39"
Weight41.7 lbs
Switch TypeManaged
Power supply includedY
Harmonized System (HS) code85176990
Access Control List (ACL)Y
SSH/SSL supportY
Authentication typeRADIUS
Design
Form factor2U
Operational conditions
Operating temperature (T-T)0 - 40 °C
Storage temperature (T-T)-40 - 70 °C
Operating relative humidity (H-H)10 - 90 %
Ports & interfaces
Basic switching RJ-45 Ethernet ports typeNone
Network
Quality of Service (QoS) supportY
Auto-sensingY
Security
Security algorithms256-bit AES
Power over Ethernet (PoE)
Power over Ethernet (PoE)N
Technical details
Product colorGray
Power
AC input frequency50/60 Hz
Number of power supply units2
Redundant power supply (RPS) supportY
Other features
Rack mountingY
Protocols
Management protocolsCLI, SSH 2, SNMP, SNMP 3, SMI-S
*
*
*
Products specifications
Attribute nameAttribute value
Installed SFP+ modules quantity96
SFP+ module slots quantity96
Width17.4"
Depth22.3"
Height3.39"
Weight41.7 lbs
Switch TypeManaged
Power supply includedY
Harmonized System (HS) code85176990
Access Control List (ACL)Y
SSH/SSL supportY
Authentication typeRADIUS
Design
Form factor2U
Operational conditions
Operating temperature (T-T)0 - 40 °C
Storage temperature (T-T)-40 - 70 °C
Operating relative humidity (H-H)10 - 90 %
Ports & interfaces
Basic switching RJ-45 Ethernet ports typeNone
Network
Quality of Service (QoS) supportY
Auto-sensingY
Security
Security algorithms256-bit AES
Power over Ethernet (PoE)
Power over Ethernet (PoE)N
Technical details
Product colorGray
Power
AC input frequency50/60 Hz
Number of power supply units2
Redundant power supply (RPS) supportY
Other features
Rack mountingY
Protocols
Management protocolsCLI, SSH 2, SNMP, SNMP 3, SMI-S