APC APDU10452SW power distribution unit (PDU) 42 AC outlet(s) Black

APC APDU10452SW. PDU types: Switched, Type: Single-phase, Product color: Black. AC outlets quantity: 42 AC outlet(s), AC outlet types: C13 coupler, C15 coupler, C19 coupler, C21 coupler. Cable length: 70.9" (1.8 m). Management platform: NMC. Nominal input voltage: 208 V, Maximum current: 60 A, AC input frequency: 50/60 Hz
Manufacturer: APC
SKU: 6571064
Manufacturer part number: APDU10452SW
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
APC NetShelter Rack PDU Advanced, Switched, 3PH, 17.3kW, 208V, 60A, 460P9, 42 Outlet APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. Switched outlets to turn outlets on or off remotely. PDU level power metering via remote access and local display for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 42 outlets in a 2.2" wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected.
APC NetShelter Rack PDU Advanced, Switched, 3PH, 17.3kW, 208V, 60A, 460P9, 42 Outlet APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. Switched outlets to turn outlets on or off remotely. PDU level power metering via remote access and local display for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 42 outlets in a 2.2" wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected.
Products specifications
Attribute nameAttribute value
Height71.9"
Weight24.5 lbs
Load Capacity17300 VA
Width2.2"
Depth2.95"
DisplayLCD
Cable Length70.9"
TypeSingle-phase
Number of phases3
Design
PDU typesSwitched
Operational conditions
Operating temperature (T-T)23 - 140 °F
Storage temperature (T-T)-25 - 65 °C
Operating relative humidity (H-H)5 - 95 %
Storage relative humidity (H-H)5 - 95 %
Operating altitude0 - 120000"
Non-operating altitude0 - 600000"
Ports & interfaces
AC outlet typesC13 coupler, C15 coupler, C19 coupler, C21 coupler
AC outlets quantity42 AC outlet(s)
Ethernet LAN (RJ-45) ports2
Technical details
Management platformNMC
Product colorBlack
Sustainability certificatesRoHS
Power
Maximum power48 W
Maximum current60 A
Nominal input voltage208 V
AC input frequency50/60 Hz
Power protection featuresOverload
Other features
Nominal output voltage208 V
Packaging data
Package height78"
Package width10.3"
Package depth5.2"
Package weight31.1 lbs
*
*
*
Products specifications
Attribute nameAttribute value
Height71.9"
Weight24.5 lbs
Load Capacity17300 VA
Width2.2"
Depth2.95"
DisplayLCD
Cable Length70.9"
TypeSingle-phase
Number of phases3
Design
PDU typesSwitched
Operational conditions
Operating temperature (T-T)23 - 140 °F
Storage temperature (T-T)-25 - 65 °C
Operating relative humidity (H-H)5 - 95 %
Storage relative humidity (H-H)5 - 95 %
Operating altitude0 - 120000"
Non-operating altitude0 - 600000"
Ports & interfaces
AC outlet typesC13 coupler, C15 coupler, C19 coupler, C21 coupler
AC outlets quantity42 AC outlet(s)
Ethernet LAN (RJ-45) ports2
Technical details
Management platformNMC
Product colorBlack
Sustainability certificatesRoHS
Power
Maximum power48 W
Maximum current60 A
Nominal input voltage208 V
AC input frequency50/60 Hz
Power protection featuresOverload
Other features
Nominal output voltage208 V
Packaging data
Package height78"
Package width10.3"
Package depth5.2"
Package weight31.1 lbs